Ophthalmic Ultrasound AB Scan SW2100 New (2 in 1)

Características

  • Modular Ophthalmic Ultrasound Platform, Allowing Probes to Be Mixed and Matched to Meet Different Needs
  • Eas-to-use Workstation Software, Friendly User Interface
  • Industry-leading Image Quality and Measurement Accuracy
  • Support DICOM 3.0

Sobre o Ultrasound AB Scan SW-2100

This A/B ultrasonic diagnostic instrument SW-2100 is an ultrasonic diagnostic instrument for the diagnosis of intraocular diseases in the eye, showing the location of the lesion, the relationship between the morphological range and the surrounding tissue, measuring the depth of the anterior chamber, the thickness of the lens, the length of the eye axis, and calculating the diopter of the implanted intraocular lens. It can diagnose intraocular diseases such as vitreous opacity, retinal detachment, and intraocular tumors. It has the characteristics of high measurement accuracy, fast measurement speed, simple and comfortable operation, large screen color LCD display and so on.

 

Parameters of Ophthalmic Ultrasound AB Scan SW2100

Frequency

10MHz, magnetic Driven, Noiseless
Scanning Mode

Sector Scanning

Ângulo de varredura

53°
Resolução

Axial≤0.2mm, Lateral≤0.3mm

Geometry Position Precision

Horizontal≤3%Vertical≤2%

Profundidade

60milímetros
Gray Levels

256

Adjustable Gain

30dB~105dB

Time Gain Control

-15dB~+15dB
Image Mode

Up to 100 Images Playback, Support Video Export in AVI Format

Magnification Function

Multi-stage Continuous Magnification, Real-time Magnification

Image Analysis Tools

False Colors, Areas, Angles, Lengths, Markers, Comments

Principal Características

SW2100 ab scan
Varredura oftalmológica de ultrassom

AB Scan SW-2100

Acessórios padrão

  • Unidade Principal
  • 10MHz uma sonda
  • 10MHz B Probe
  • Workstation

SW-2100 Parâmetro Técnico

Frequency

10MHz, with LED
Profundidade

40milímetros

Precisão

±0.04mm
Measurement Parameters

Profundidade da Câmara Anterior, Espessura da lente, Vitreous Thickness, Axial Length

Adjustable Gain

30dB~105dB
Time Gain Control (TGC)

-15dB~+15dB

Reports

Record up to 10 Measurement Results, Automatic Calculation of Average, Standard Deviation, Maximum and Minimum of the Results

Eye Types

Phakic, Aphakic,PMMA, Silicone, Acrylic

Fórmula LIO

SRK-II, SRK-T, HOFFER-Q, FERIADO, BINKHORST-II, HAIGIS

Agora deixe-nos saber suas necessidades